Infrastructure & Sub-Grade Networks
Expansive sub-grade civil engineering, medium-voltage (MV) reinforced utility culverts, stormwater networks, water distribution pipelines, and mass rock earthworks executed for major Saudi developments.
Sub-grade utility corridors engineered for generational durability.
MV-Culverts & Duct Banks
Multi-way PVC/HDPE encased duct banks, monolithic reinforced concrete utility tunnels, SEC-compliant manholes, and cable joint bays built for 33kV distribution.
- SEC & Aramco specification compliance
- Mandrel proof testing for conduit alignment
Stormwater & Drainage Systems
High-capacity precast box culverts, cast-in-place open drainage channels, perforated sub-surface collector pipes, oil-water separators, and storm detention vaults.
- Laser gradient control within 0.1% fall
- Geotextile wrapped aggregate filter beds
Potable & Firefighting Mains
Ductile iron Class K9/C40 pipelines, high-density polyethylene (HDPE 100-RC) butt-fused mains, isolation valve chambers, air release assemblies, and hydrants.
- 16-bar hydrostatic pressure testing
- Civil Defense approved fire ring mains
Bulk Earthworks & Rock Trenching
Mass excavation in hard sedimentary limestone, ripper bulldozer leveling, bench cutting, engineered fill compaction in 250mm loose layers, and slope shoring.
- Plate load & nuclear density logging
- GPS-guided grading systems (CAT AccuGrade)
Roads, Sub-base & Paving
Crushed aggregate base course (Class A/B), asphalt concrete binder (Superpave SP-19), asphalt wearing course (SP-12.5), concrete interlock paving, and granite curbs.
- Marshal stability & flow analysis
- Straight-edge rideability tolerance (≤ 3mm)
Trench Waterproofing & Epoxy Protection
Sub-grade concrete waterproofing, hot-applied elastomer bitumens, protective heavy-duty polyurethane coatings, and chemical-resistant culvert floor toppings.
- DCP & Fosroc certified systems
- Spark holiday testing for pinhole absence
Earthwork & Pipeline Inspection Protocols
| Infrastructure Parameter | Standard Code | Inspection Method | Acceptance Specification |
|---|---|---|---|
| Sub-base & Backfill Compaction | ASTM D1557 / D6938 | Nuclear density gauge test every 250m² per lift | ≥ 98% Maximum Dry Density (MDD); moisture within ±2% OMC |
| Pressure Line Hydrostatic Test | AWWA C600 / ISO 10802 | Calibrated digital gauge hold for 4 hours continuous | Test pressure = 1.5x working pressure (min 15 bar); zero drop in gauge reading |
| Gravity Pipe Alignment & Deflection | ASTM F1216 / EN 1610 | CCTV robotic crawler inspection + 5% mandrel pull | Zero obstruction, full circularity within 5% internal diameter tolerance |
| Culvert Surface DFT Coating | SSPC-PA 2 / ASTM D4414 | PosiTector electromagnetic dry film gauge | DFT ≥ 600μm two-coat epoxy; 100% pinhole-free via holiday detection |
Delivered Infrastructure Projects
DG-II Infra, Package 1: MV-Culvert Infrastructure
Sub-grade medium voltage utility corridors, trench excavation, monolithic conduit casting, and high-performance certified epoxy sealing.